- Enlarged plan view (Horizontal Section) of shafts, pits and machine rooms at 3/8" scale minimum fully dimensioned and construction indicated. Indicate pit and hoistway dimensions.
- Column Reference Grids on Enlarged Plans and Sections.
- Indication of North on all Enlarged Plans.
- Section or sections through shaft
- Indicate "Section Designations" on Enlarged Plans.
- Head, Jamb and Sill Details
- Referenced from Sections.
- Supports for Guide Rails.
- Elevator Pit Sumps.
- Coordinate Voltage with Electrical.
- Detail Special Cabs.
- Ladders for Pit - Check elevator codes.
- Waterproofing for Pit - on inside or outside.
- Access doors and panels to hoistways, pits, machine rooms, etc. - Check codes.
- Transom Panel Details if not "stock" items.
- Ventilation locations if possible - Check codes.
- Fire Rating Requirements of shaft enclosure.
- Handicapped considerations.
- "Drawing Title Designation" on all Enlarged Plans, or Sections, etc.
- Coordinate closely with Project Manual as to the function, accessories, etc.
- Coordinate items in Elevator Section 14200 of Project Manual with Electrical Division 16.